Summary for Test 2025-06-07-3-5
Test performed: AASHTO T84-14Project Information
| Project Identifiers | Project ID: 1001312 DEA: 11432844 EFIS: 1125000219 |
|---|---|
| DIST-CO-RTE-PM | 11--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/07/2025 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2025 |
| Sample type | Verification | A brief description of the sample | JMFV |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-06-07-3-JMFV | Linked DIME Sample ID | 2025-06-07-2 |
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Provided |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 224114 Vulcan Otay |
Test Details
DIME Sample ID: 2025-06-07-3
DIME Test ID: 2025-06-07-3-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2025-06-12
Test Results
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 06/11/2025
Mass of saturated surface dry sample (before pycnometer) (S): 500.0 grams
Mass of the pycnometer with water and aggregate (C): 989.8 grams
Mass of the pycnometer with water (B): 680.3 grams
Mass of the oven dried sample (before pycnometer) (A): 489.6 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.0 grams
Mass of the oven dry aggregate (for absorption) (A): 489.6 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.570
Bulk specific gravity (SSD Basis): 2.625
Apparent specific gravity: 2.718
Absorption: 2.1 %
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 6/12/2025 ✔