Summary for Test 2025-05-07-61-9
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 214627 DEA: 05344904 EFIS: 0500000505 |
|---|---|
| DIST-CO-RTE-PM | 05-SBT-156-3/R8.2 |
| Award Date | 05/19/2022 |
| Closeout Date | Not set |
| Work Description | SAN BENITO ROUTE 156 IMPROVEMENT PROJECT SAN BENITO RTE 156 IMPROVEMENT PROJECT; INCLUDES NEW BRIDGE AND WIDENING OF EXISTING BRIDGE. |
| Location Description | SAN BENITO COUNTY IN AND NEAR SAN JUAN BAUTISTA FROM THE ALAMEDA TO 0.2 MILE EAST OF FOURTH STREET/BUSINESS ROUTE 156 |
| QA Service Level | 1 (Verified on 01/14/2020) |
Sample Information
| Sample Taken Date | 05/07/2025 | Sample Unique Key | 61 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/13/2025 |
| Sample type | Informational | A brief description of the sample | PG 64-28M |
| The quantity of what the sample constitutes | 1 of 2 Cans | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | A | Last name of sampler or witnessed by | Romiza |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Vernalis | Transportation Laboratory (TL) Number | 0507251 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
|---|---|---|---|
| Modified | No | Lot number | 1 |
| Sublot number | 4 | Tank number | |
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-05-07-61
DIME Test ID: 2025-05-07-61-9
Testing Lab: WSP USA - Phoenix
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-02-04
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Luis Maca
Date of test: 06/12/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 203.140 grams
Mass of container #2 before test (m2i): 201.387 grams
Mass of container #1 after test (m1f): 202.991 grams
Mass of container #2 after test (m2f): 201.241 grams
Mass of empty container #1: 168.443 grams
Mass of empty container #2: 166.523 grams
Mass correction factor: 0.006
Average mass change: -0.418 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change
Test was verified on 2/4/2026 ✔