Summary for Test 2025-06-03-18-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994326 DEA: 051C3604 EFIS: 0512000134 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-217-0.9/1.4 |
| Award Date | 01/31/2023 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 10/17/2022) |
Sample Information
| Sample Taken Date | 06/03/2025 | Sample Unique Key | 18 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2025 |
| Sample type | Quality Assurance | A brief description of the sample | #8 HRC 500/510 Couplers |
| The quantity of what the sample constitutes | 1 Sample from 2 lots | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | (916) 767-3535 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Integrity Rebar Placers | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-045-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Vinton Steel |
| Coupler Manufacturer | HRC Fountain Valley | Intermediate Assembler or Fabricator | Integrity Rebar Placers |
| Rebar Size | #8 | Coupler Model | HRC 500/510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | A230687, A226108, 5395277 | Rebar Heat Number(s) | 2320677 |
| Rebar Size 2 | 8 | Coupler Unique ID | TP-17-03 |
Test Details
DIME Sample ID: 2025-06-03-18
DIME Test ID: 2025-06-03-18-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-06-12
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 06/12/2025
UTM: NA
Halo ID: na
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 3 | 8 | 0.79 | 0.001 | 73970 | 93500 | ok necking | Kleinfelder |
| 2 | 2 | 3 | 8 | 0.79 | 0000 | 73210 | 92500 | ok necking | Kleinfelder |
| 3 | 3 | 3 | 8 | 0.79 | 0000 | 72770 | 92000 | ok necking | Kleinfelder |
| 4 | 4 | 3 | 8 | 0.79 | 0000 | 72990 | 92500 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/12/2025 ✔