Summary for Test 2025-05-07-103-3

Test performed: ASTM D5329-20

Project Information

Project IdentifiersProject ID: 994781
DEA: 07322704
EFIS: 0716000067
DIST-CO-RTE-PM07-VEN-1-1.3/26.6
Award Date01/31/2023
Closeout DateNot set
Work DescriptionCONSTRUCT PERVIOUS CONCRETE PAVEMENT
Location DescriptionVENTURA COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/13/2023)

Sample Information

Sample Taken Date05/07/2025 Sample Unique Key103
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/13/2025
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byChristian Last name of sampler or witnessed bychristian Vulcan QC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sun Valley - Blvd. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2025-05-07-103
DIME Test ID: 2025-05-07-103-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2025-07-02

Test Results


Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 06/11/2025
Temperature: 25 C
Ball Penetration (P1): 1 mm
Final Dial reading (F1): 60 mm
Ball Penetration (P2): 1 mm
Final Dial reading (F2): 56 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 57 mm
Resilience 1: 41 %
Resilience 2: 45 %
Resilience 3: 43 %
Average Resilience: 43 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/2/2025