Summary for Test 2017-10-19-13-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211673 DEA: 120M3504 EFIS: 1212000018 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-405-2.6/6.5 |
| Award Date | 11/29/2016 |
| Closeout Date | 06/29/2020 |
| Work Description | EXTD 2ND AUX LN ON SB 405, REPL EXIST K-RAIL TO TYPE 60/60C CONC BARR |
| Location Description | ORANGE COUNTY IN IRVINE FROM 0.3 MILE SOUTH OF SAND CANYON AVENUE OVERCROSSING TO 0.4 MILE SOUTH OF JAMBOREE ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/24/2017) |
Sample Information
| Sample Taken Date | 10/19/2017 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Barsplice Griptwist coupler |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Kugan | Last name of sampler or witnessed by | Ramanathan |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Barsplice | Transportation Laboratory (TL) Number | C385419 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Gerdau |
| Coupler Manufacturer | Barsplice | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | 8 | Coupler Model | Grip Twist |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | 177356, 177248 | Rebar Heat Number(s) | 65026170 |
| Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-10-19-13
DIME Test ID: 2017-10-19-13-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-11-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/27/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 1 | #8/25mm | 0.79 | 0 | 74222 | 93952 | OK Necking | Fred |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 10/27/2017 ✔