Summary for Test 2023-01-25-65-2
Test performed: AASHTO T336-15Project Information
| Project Identifiers | Project ID: 993529 DEA: 11430514 EFIS: 1119000008 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-15-R31.3/R37.1 |
| Award Date | 05/27/2022 |
| Closeout Date | Not set |
| Work Description | CRCP, FIBER OPTIC CABLE, AND HMA. |
| Location Description | SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/07/2022) |
Sample Information
| Sample Taken Date | 01/25/2023 | Sample Unique Key | 65 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/26/2023 | Sample type | Quality Control |
| A brief description of the sample | 4x8 concrete cylinders | The quantity of what the sample constitutes | 2 |
| From where was the sample collected | Source | First name of sampler or witnessed by | James |
| Last name of sampler or witnessed by | Rogers | Title of sampler | QC Field Technician |
| Telephone number of sampler | Laboratory sample identification | RD2271-CA-120 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Security Paving | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | G3-22-PCC-328HP |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 0 | |
| Concrete batch plant | Security Paving | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Onsite Batch Plant | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-01-25-65
DIME Test ID: 2023-01-25-65-2
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Test Release Date: 2025-06-10
Test Results
Input Type: Calculated
Tester's full name: Mario Salazar
Date of test: 03/08/2023
Average CTE: 0.000008876 mm/mm/°C
Average CTE: 4.931E-6 in/in/°F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/10/2025 ✔