Summary for Test 2025-05-29-44-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000661
DEA: 081J2704
EFIS: 0818000014
DIST-CO-RTE-PM08-SBD-247-0.0/23.0
Award Date01/31/2025
Closeout DateNot set
Work DescriptionRUBBERIZED HMA, HMA (TYPE A), COLD PLANE AC PVMT & REPLACE AC SURF.
Location DescriptionSAN BERNARDINO COUNTY IN YUCCA VALLEY FROM ROUTE 62 TO 0.4 MILE WEST OF GIN ROAD
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date05/29/2025 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2025
Sample typeAcceptance A brief description of the sample3/4" HMA A R25 0.6% EVO
The quantity of what the sample constitutes4 BOXES OF HMA, 1 QT PG64-16 From where was the sample collectedManufacturer
First name of sampler or witnessed byBenjamin Last name of sampler or witnessed byBD - QC
Title of sampler Telephone number of sampler
Laboratory sample identification0324A-25 Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Diamond-Victorville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number14 HMA Mix Number300154 R25
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-05-29-44
DIME Test ID: 2025-05-29-44-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-06-09

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 06/05/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2176.1 g
Mass Loss: 121.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.51 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.96 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/9/2025