Summary for Test 2025-05-30-17-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000751
DEA: 060Y1704
EFIS: 0619000004
DIST-CO-RTE-PM06-KIN-41-0.0/15.5
Award Date03/03/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, OVERLAY HMA AND RHMA.
Location DescriptionKINGS COUNTY NEAR KETTLEMAN CITY FROM THE KERN COUNTY LINE TO 0.8 MILE SOUTH OF ROUTE 5
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date05/30/2025 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2025
Sample typeAcceptance A brief description of the sampleType II-V Cement
The quantity of what the sample constitutes8 cy From where was the sample collectedJob Site
First name of sampler or witnessed bySok Last name of sampler or witnessed byThun
Title of samplerASR Telephone number of sampler5592402128
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalportland Lemoor Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier45-0036
Structure nameBarrier Rail Transition Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number163457
The truck number from where the sample was collected0697 The batch plant ticket number from where the sample was collected239741
Concrete batch plantLemoore Plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampledBarrier Rail Transition (Wall)
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-05-30-17
DIME Test ID: 2025-05-30-17-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-06-09

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 06/06/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 45080 lb
Maximum load on cylinder 2: 41220 lb
Maximum load on cylinder 3: 42460 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 3552.4 psi
Compressive strength of cylinder 2: 3263.7 psi
Compressive strength of cylinder 3: 3361.8 psi
Compressive strength (to nearest 10 psi): 3390 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/9/2025