Summary for Test 2025-05-07-66-6

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 995538
DEA: 024H0604
EFIS: 0218000073
DIST-CO-RTE-PM02-PLU,PLU-36-
Award Date11/05/2024
Closeout DateNot set
Work DescriptionCHESTER CAUSEWAY REHAB
Location DescriptionLASSEN AND PLUMAS COUNTIES FROM MELISSA AVENUE TO 0.6 MILE EAST OF RED RIVER CANAL
QA Service Level1 (Verified on 10/24/2024)

Sample Information

Sample Taken Date05/07/2025 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/16/2025
Sample typeQuality Assurance A brief description of the samplePG 58-34
The quantity of what the sample constitutes2 cans From where was the sample collectedJob Site
First name of sampler or witnessed byJoe Last name of sampler or witnessed byDelgado
Title of samplerConsultant Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina - Klamath Falls, OR Transportation Laboratory (TL) Number859028
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierAlbina Asphalt (Klamath Falls Plant) - Klamath Falls OR MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-05-07-66
DIME Test ID: 2025-05-07-66-6
Testing Lab: Atlas - Denver
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-06-06

Test Results


Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: Atlas
Date of test: 06/02/2025
Time of test: 09:00 HH:MM
Test Temperature: 135.0 C
Speed: 20 rpm
Spindle size: .463 in
Torque: 12.1 %
Viscosity reading #1 (A) : 302.5 cP
Viscosity reading #2 (B) : 302.5 cP
Viscosity reading #3 (C): 302.5 cP
Average viscosity : 0.303 Pa-s
General comments (publicly viewable) (Max 1000 characters): Viscosity @135C

Test was verified on 6/6/2025