Summary for Test 2025-05-17-16-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Sample Information

Sample Taken Date05/17/2025 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/17/2025
Sample typeQuality Assurance A brief description of the sample3 RSC beams
The quantity of what the sample constitutes10 CY From where was the sample collectedJob Site
First name of sampler or witnessed byJeffrey Last name of sampler or witnessed byDiaz
Title of samplerMaterials Tester Telephone number of sampler5622547835
Laboratory sample identification25-1620 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSM446B2R
The truck number from where the sample was collectedTruck 5 The batch plant ticket number from where the sample was collectedLoad 3
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-05-17-16
DIME Test ID: 2025-05-17-16-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-06-05

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Stress
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Jeffrey Diaz
Date of test: 05/27/2025
Identification number: 25-1620
Width of specimen: 6.125 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 5.9375 inch
Depth of specimen 2: 5.9375 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum recording: 780 psi
Maximum recording 2: 760 psi
Maximum recording 3: 790 psi
Correction Factor: 1
Correction Factor 2: 1.02
Correction Factor 3: 1
Curing history and apparent moisture condition of the specimen: Sand
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 820 psi
Modulus of rupture 2: 810 psi
Modulus of rupture 3: 830 psi
Modulus of rupture average: 820 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/5/2025