Summary for Test 2025-05-19-74-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995119
DEA: 034H6004
EFIS: 0319000004
DIST-CO-RTE-PM03-PLA-49-R8.7/R10.6
Award Date12/08/2023
Closeout DateNot set
Work DescriptionCONC BARRIER, JPCP, HMA, RDWY EXC, RCP AND LIGHTING.
Location DescriptionPLACER COUNTY NEAR AUBURN FROM 0.3 MILE SOUTH OF LORENSEN ROAD/FLORENCE LANE TO 0.4 MILE NORTH OF LONE STAR ROAD
QA Service Level1 (Verified on 11/13/2023)

Sample Information

Sample Taken Date05/19/2025 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2025
Sample typeProduction Start-Up A brief description of the sample10 Boxes
The quantity of what the sample constitutes3/4" HMA w/ 25% RAP From where was the sample collectedSource
First name of sampler or witnessed bySergio Last name of sampler or witnessed byTostado
Title of sampler Telephone number of sampler
Laboratory sample identificationPSU25-047 Linked DIME Sample ID2025-05-19-69
The fabricator/manufacturer/facility nameDesilva Gates-Marysville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix NumberMD 6736
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-05-19-74
DIME Test ID: 2025-05-19-74-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-06-04

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 05/30/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2190.0 g
Mass Loss: 129.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.68 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.23 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/4/2025