Summary for Test 2017-10-18-5-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | Project ID: 212756 DEA: 65A0617 |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Type 15 FBS , ST-75 Bridge Rail, Type 85 Concrete Bridge Rail |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/18/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2017 |
| Sample type | Quality Assurance | A brief description of the sample | F1554 anchor rods |
| The quantity of what the sample constitutes | 24 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Lanz |
| Title of sampler | QA | Telephone number of sampler | 7072085241 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L106-007-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | ||
| Washer Mfg. Lot Number(s) | Bolt Specification | NA | |
| Bolt Length(s) | Nut Specification | A325-DH | |
| Washer Specification | NA | Finish | |
| Diameter/Size | Bolt Mfg. Lot Number | ||
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-10-18-5
DIME Test ID: 2017-10-18-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-11-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/26/2017
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 3/4\" | 0.334 | 49112 | 218 | 147042 | 135344 | 45205 | F 1554 Gr 105 |
General comments (publicly viewable) (Max 1000 characters): F 1554 Gr 105
Test Graph
Source: Partner Data Point FileTest was verified on 10/27/2017 ✔