Summary for Test 2025-05-28-35-3

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 1000751
DEA: 060Y1704
EFIS: 0619000004
DIST-CO-RTE-PM06-KIN-41-0.0/15.5
Award Date03/03/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, OVERLAY HMA AND RHMA.
Location DescriptionKINGS COUNTY NEAR KETTLEMAN CITY FROM THE KERN COUNTY LINE TO 0.8 MILE SOUTH OF ROUTE 5
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date05/28/2025 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/28/2025
Sample typeAcceptance A brief description of the sampleCon aggs
The quantity of what the sample constitutes4cy From where was the sample collectedManufacturer
First name of sampler or witnessed byNoah Last name of sampler or witnessed byHunt
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCal portland Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Cal portland lemoore
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile at plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-05-28-35
DIME Test ID: 2025-05-28-35-3
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2025-06-04

Test Results


Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 06/02/2025
Top sediment column reading (single primary size): 0.4 in
Cleanness value (single primary size): 89
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/4/2025