Summary for Test 2025-04-17-64-7
Test performed: SMTL BILST-06Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/17/2025 | Sample Unique Key | 64 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/28/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 5" Joint Seal |
| The quantity of what the sample constitutes | 300' | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Simon |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Watson Bowman Acme | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0925184 |
|---|---|---|---|
| Manufacturer(s) | Watson Bowman Acme | Temperature | 72 |
| Humidity | 50 | Comments | |
| Joint Seal Size | 5 |
Test Details
DIME Sample ID: 2025-04-17-64
DIME Test ID: 2025-04-17-64-7
Testing Lab: Phoenix National Lab
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Test Release Date: 2025-06-12
Test Results
Input Type: Calculated
Tester's full name: Andrew Auvinen
Date of test: 06/02/2025
Result: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/12/2025 ✔