Summary for Test 2017-10-18-3-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 212756 DEA: 65A0617 |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Type 15 FBS , ST-75 Bridge Rail, Type 85 Concrete Bridge Rail |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/18/2017 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Bolt Assembly |
| The quantity of what the sample constitutes | 18 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Lanz |
| Title of sampler | QA | Telephone number of sampler | 7072085241 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L106-005-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0093088 |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | Unytite 25982-6214369502 | |
| Washer Mfg. Lot Number(s) | Prestige D3578 | Bolt Specification | A325-1 |
| Bolt Length(s) | 5-1/2" | Nut Specification | HVY HEX NUT A563-DH |
| Washer Specification | F436-1 Structural Washer | Finish | HDG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | SLSB BG0743 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Yes | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-10-18-3
DIME Test ID: 2017-10-18-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-11-03
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/26/2017
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | BG0743 | 3/4\" | 48002 | 213.5 | 10 | A325 | Brian |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 10/27/2017 ✔