Summary for Test 2025-05-29-41-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000911
DEA: 061G7104
EFIS: 0624000158
DIST-CO-RTE-PM06-FRE-5,33-49.9/55.7,16.8/22.8
Award Date03/28/2025
Closeout Date12/02/2025
Work DescriptionPAVEMENT DELINEATION.
Location DescriptionFRESNO COUNTY NEAR COALINGA ON ROUTE 33 FROM PHELPS AVENUE TO 1.6 MILES SOUTH OF ROUTE 198 AND ON ROUTE 5 FROM 1.0 MILE NORTH OF PANOCHE ROAD OVERCROSSING TO 0.2 MILE NORTH OF CALIFORNIA AVE OVERCROSSING
QA Service Level1 (Verified on 02/11/2025)

Sample Information

Sample Taken Date05/29/2025 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/29/2025
Sample typeAcceptance A brief description of the sample3 concrete beams RSC
The quantity of what the sample constitutes2 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byJonathon Last name of sampler or witnessed byChaney
Title of samplerTET Telephone number of sampler5592309471
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePave Tech Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedWheelbarrow from Chute volumetric truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-05-29-41
DIME Test ID: 2025-05-29-41-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-06-02

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 06/02/2025
Identification number: Set 1
Width of specimen: 6.0625 inch
Width of specimen 2: 6.125 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.125 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9290 lb
Maximum load applied 2: 9080 lb
Maximum load applied 3: 9580 lb
Correction Factor: 1
Correction Factor 2: 1
Correction Factor 3: 1
Curing history and apparent moisture condition of the specimen: moist
If specimen was capped, ground or if leather shims were used: leather shims
Defects in specimen, including numbers of beams discarded during test: N/A
Age of specimen: 4 days
Age of specimen in hours: no data
Modulus of rupture: 770 psi
Modulus of rupture 2: 750 psi
Modulus of rupture 3: 800 psi
Modulus of rupture average: 770 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/2/2025