Summary for Test 2025-05-10-4-5
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 1000346 DEA: 081N6904 EFIS: 0823000037 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15-36.6/37.0 |
| Award Date | 01/23/2025 |
| Closeout Date | 07/22/2025 |
| Work Description | HMA, ROADWAY EXCAVATION, CLASS 2 AB, REMOVE BASE & SURFACING, RHMA. |
| Location Description | RIVERSIDE COUNTY IN CORONA FROM 0.2 MILE SOUTH TO 0.2 MILE NORTH OF CAJALCO ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 05/10/2025 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4" WMA A SP R25 0.25% EVO |
| The quantity of what the sample constitutes | 18 BX HMA 2 QT PG64-16 3 BG CMB AG 1 BG RAP | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | VULCAN | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0292A-25 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 221528W CORD SJR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-05-10-4
DIME Test ID: 2025-05-10-4-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2025-06-02
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Elias Hamel
Date of test: 05/21/2025
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Untreated | ||||||
275 psi | 277 psi | |||||
99.5 | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/2/2025 ✔