Summary for Test 2025-05-10-4-2

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 1000346
DEA: 081N6904
EFIS: 0823000037
DIST-CO-RTE-PM08-RIV-15-36.6/37.0
Award Date01/23/2025
Closeout Date07/22/2025
Work DescriptionHMA, ROADWAY EXCAVATION, CLASS 2 AB, REMOVE BASE & SURFACING, RHMA.
Location DescriptionRIVERSIDE COUNTY IN CORONA FROM 0.2 MILE SOUTH TO 0.2 MILE NORTH OF CAJALCO ROAD OVERCROSSING
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date05/10/2025 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2025
Sample typeProduction Start-Up A brief description of the sample3/4" WMA A SP R25 0.25% EVO
The quantity of what the sample constitutes18 BX HMA 2 QT PG64-16 3 BG CMB AG 1 BG RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byVULCAN Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0292A-25 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number221528W CORD SJR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-05-10-4
DIME Test ID: 2025-05-10-4-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-06-02

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Eddie Bidinger
Date of test: 05/17/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7326.1 grams
Mass of oven-dry sample in air for Sample 1: 2545.0 grams
Mass of container filled with the sample and water for Sample 1: 8858.4 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.513
Theoretical maximum density at 25°C (77°F): 2506 kg/m^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/2/2025