Summary for Test 2025-05-01-42-6
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994688 DEA: 070W2904 EFIS: 0721000235 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-101-1.5/10.9 |
| Award Date | 06/08/2023 |
| Closeout Date | Not set |
| Work Description | DECK METHACRYLATE, JOINT SEAL REPLACEMENT, AC SURFACING, SPALL REPAIR. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 07/13/2023) |
Sample Information
| Sample Taken Date | 05/01/2025 | Sample Unique Key | 42 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/06/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 3/8" HMA A SP R15 PG64-10 |
| The quantity of what the sample constitutes | 20 BX HMA, 4 QT PG64-10, 4 BG CMB AGG, 2 BG RAP | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | VICTOR | Last name of sampler or witnessed by | PHAM |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0275A-25 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | AAA-Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/8 inch | Lot number | |
| Sublot number | HMA Mix Number | 109726 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-05-01-42
DIME Test ID: 2025-05-01-42-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-05-30
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 05/08/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1339.8 g
Mass Loss: 83.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.27 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.22 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.70 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/30/2025 ✔