Summary for Test 2025-04-29-58-4
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 995060 DEA: 081J2604 EFIS: 0818000012 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-215-R13.5/R19.5 |
| Award Date | 01/10/2024 |
| Closeout Date | Not set |
| Work Description | RHMA, REPLACE AC SURFACING, ROCK BLANKET, AND COMPOST. |
| Location Description | RIVERSIDE COUNTY IN MURRIETA AND MENIFEE FROM 1.0 MILE NORTH OF CLINTON KEITH ROAD TO 1.0 MILE NORTH OF NEWPORT ROAD |
| QA Service Level | 1 (Verified on 08/15/2023) |
Sample Information
| Sample Taken Date | 04/29/2025 | Sample Unique Key | 58 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/06/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4" HMA A SP R25 0.25% EVO |
| The quantity of what the sample constitutes | 18 BX HMA, 1 QT PG64-16, 1 QT EVO, 2 BGSS CMB AGG, 1 BG RAP | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | JACOB | Last name of sampler or witnessed by | RJ Noble QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0274A-25 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | RJ Noble Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 36R2503SPWEC | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-04-29-58
DIME Test ID: 2025-04-29-58-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-05-30
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method:
Input Type: Calculated
Tester's full name: Eddie Bidinger
Date of test: 05/10/2025
Average impression at 5000 passes (left/right avg): 1 mm
Average impression at 10000 passes (left/right avg): 1.2 mm
Average impression at 15000 passes (left/right avg): 1.3 mm
Raw Data: no data
Average impression at 20000 passes (left/right avg): 1.44 mm
Average impression at 25000 passes (left/right avg): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/30/2025 ✔