Summary for Test 2025-05-11-4-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000681
DEA: 081J7204
EFIS: 0818000099
DIST-CO-RTE-PM08-SBD-40-S0.0/S0.8,0.0/R15.0
Award Date01/17/2025
Closeout Date09/03/2026
Work DescriptionREPLACE AC SURFACING, COLD PLANE AC PAVEMENT, HMA, RSP, AND MGS.
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR BARSTOW FROM 0.1 MILE WEST OF ROBERTA STREET TO MONTARA ROAD AND FROM ROUTE 15 TO 0.4 MILE EAST OF LAVA WASH BRIDGE
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date05/11/2025 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing05/13/2025 Sample typeAcceptance
A brief description of the sample3/4" RHMA G SSP 1.0% LSM The quantity of what the sample constitutes8 BOXES OF RHMA, 1 QTPG64-16, 1 QT RUBBER BLEND
From where was the sample collectedManufacturer First name of sampler or witnessed byFrancisco
Last name of sampler or witnessed byRUVALCABA Title of sampler
Telephone number of sampler Laboratory sample identification0288G-25
Linked DIME Sample ID The fabricator/manufacturer/facility nameBlue Diamond-Victorville
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number35 HMA Mix Number300072 LSM
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-05-11-4
DIME Test ID: 2025-05-11-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-05-29

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Elias Hamel
Date of test: 05/15/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2134.1 g
Mass Loss: 167.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.17 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.53 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/29/2025 ✔