Summary for Test 2025-05-28-15-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 1000301
DEA: 07333704
EFIS: 0716000316
DIST-CO-RTE-PM07-LA-138-43.4/51.4
Award Date07/30/2024
Closeout DateNot set
Work DescriptionCONSTRUCT ADA CURB RAMPS, SIDEWALK, AND DRIVEWAY.
Location DescriptionLOS ANGELES COUNTY IN PALMDALE FROM ROUTE 14 JUNCTION (SOUTH) TO AVENUE T
QA Service Level1 (Verified on 08/12/2024)

Sample Information

Sample Taken Date05/28/2025 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/28/2025
Sample typeAcceptance A brief description of the sampleCR#44 at aprox sta.2646+00 at intersection of Ave S and 47th St.
The quantity of what the sample constitutes43 SY From where was the sample collectedJob Site
First name of sampler or witnessed bySopheak Last name of sampler or witnessed byChong
Title of samplerTEC Telephone number of sampler2138170174
Laboratory sample identification25-1690 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameCR#44 at aprox sta.2646+00 at intersection of Ave S and 47th St. Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleAggregate Base
The fabricator/manufacturer designation for the samplevarious location A.B A detailed description of where the material sample was collectedJobsite
Where the material sample would have been placed if not sampledJobsite

Test Details

DIME Sample ID: 2025-05-28-15
DIME Test ID: 2025-05-28-15-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-05-29

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Sopheak Chong
Date of test: 05/29/2025
Gage No.: 60137
Test No.: 1
Nuclear By: Sopheak Chong
Non-Bias Plan No.: 2
Depth: 3''
Material No.: Aggregate Base
Material Type: Aggregate Base
Impact By: Sopheak Chong
Standard Count Density: 2165 g/cc
Count or Density 1: 1.94 g/cc
Count or Density 2: 2.01 g/cc
Count or Density 3: 2.05 g/cc
Standard Count Moisture: 626 g/cc
Moisture Count 1: 0.22 g/cc
Moisture Count 2: 0.33 g/cc
Moisture Count 3: 0.19 g/cc
Sum of Count or Density: 6 g/cc
Average of Count or Density: 2 g/cc
Sum of Moisture Count: 0.74 g/cc
Average of Moisture Count: 0.25 g/cc
Calculated Percent Relative Compaction: 94.8 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/29/2025