Summary for Test 2025-05-11-10-3

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 995193
DEA: 07356604
EFIS: 0719000026
DIST-CO-RTE-PM07-LA-605-R10.2/20.2
Award Date04/04/2024
Closeout DateNot set
Work DescriptionLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
QA Service Level1 (Verified on 10/03/2023)

Sample Information

Sample Taken Date05/11/2025 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/11/2025
Sample typeQuality Assurance A brief description of the sample6 x 12 LCB Cylinders
The quantity of what the sample constitutes10 CY From where was the sample collectedJob Site
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byArroyo
Title of samplerMaterials Tester Telephone number of sampler7605743880
Laboratory sample identification25-1511 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberVCTS675
The truck number from where the sample was collectedTruck 2201 The batch plant ticket number from where the sample was collectedLoad 1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-05-11-10
DIME Test ID: 2025-05-11-10-3
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-05-28

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Stress
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Jeffrey Diaz
Date of test: 05/14/2025
Identification number: 25-1511
Width of specimen: 6.125 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum recording: 580 psi
Maximum recording 2: 570 psi
Maximum recording 3: 585 psi
Correction Factor: 0.94
Correction Factor 2: 1
Correction Factor 3: 1
Curing history and apparent moisture condition of the specimen: Sand
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 570 psi
Modulus of rupture 2: 600 psi
Modulus of rupture 3: 610 psi
Modulus of rupture average: 590 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/28/2025