Summary for Test 2024-11-21-73-1

Test performed: ASTM C39-18

Project Information

Project IdentifiersProject ID: 994903
DEA: 11430244
EFIS: 1118000033
DIST-CO-RTE-PM11-SD-125-9.3/13.0
Award Date09/06/2023
Closeout DateNot set
Work DescriptionPLACE HMA, RHMA, SLAB REPLACEMENT, AND ELECTRICAL WORK.
Location DescriptionSAN DIEGO COUNTY IN AND NEAR LEMON GROVE FROM 0.3 MILE SOUTH OF ELKELTON PLACE UNDERCROSSING TO 0.2 MILE SOUTH OF ROUTE 125/94 SEPARATION
QA Service Level1 (Verified on 11/14/2023)

Sample Information

Sample Taken Date11/21/2024 Sample Unique Key73
Date that the sample was received by the laboratory/organization performing the testing11/22/2024 Sample typeQuality Control
A brief description of the samplestructural concrete The quantity of what the sample constitutes2 cylinders
From where was the sample collectedJob Site First name of sampler or witnessed byRobert
Last name of sampler or witnessed byCota Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertsons RM EL Cajon plant 29
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberRRM23117
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1190223
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOS CMS 1 foundation RTE 25 in Lemon Grove Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-21-73
DIME Test ID: 2024-11-21-73-1
Testing Lab: Sequoia Consultants
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-05-27

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Kendrict Sancha
Date of test: 12/19/2024
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Maximum load on cylinder 1: 117520 lb
Maximum load on cylinder 2: 116280 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4140 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/27/2025 ✔