Summary for Test 2025-05-09-12-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 1000409
DEA: 051S1604
EFIS: 0524000176
DIST-CO-RTE-PM05-MON-1-60
Award Date06/14/2024
Closeout Date08/21/2026
Work DescriptionRocky Creek Slip Out Permanent Restoration Project
Location DescriptionNot set
QA Service Level1 (Verified on 06/26/2024)

Sample Information

Sample Taken Date05/09/2025 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing05/15/2025 Sample typeQuality Assurance
A brief description of the sample8 Samples (4 ea. from total of 4 lots) of #5 Rebar with EL16SAES Form Savers The quantity of what the sample constitutes8
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byAlvarez Title of samplerQuality Assurance Inspector
Telephone number of sampler2094301848 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin Steel
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturernVent Lenton Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelnVent Lenton Form Saver
Coating StandardsASTM A775 epoxy Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)M0006 Rebar Heat Number(s)1202062533, 1201061114
Rebar Size 2 Coupler Unique IDST-17-05

Test Details

DIME Sample ID: 2025-05-09-12
DIME Test ID: 2025-05-09-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-05-27

Test Results


Number of Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 05/27/2025
UTM: NA
Halo ID: na
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111-450.310.0042926094500service spliceKleinfelder
221-450.3100002907094000service spliceKleinfelder
331-450.3100002957095500service spliceKleinfelder
441-450.3100002968095500service spliceKleinfelder
511-450.310.0062918094000service spliceKleinfelder
621-450.3100002936094500service spliceKleinfelder
731-450.3100002938095000service spliceKleinfelder
841-450.3100002982096000service spliceKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/27/2025 ✔