Summary for Test 2025-05-09-11-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 1000409
DEA: 051S1604
EFIS: 0524000176
DIST-CO-RTE-PM05-MON-1-60
Award DateNot set
Closeout DateNot set
Work DescriptionRocky Creek Slip Out Permanent Restoration Project
Location DescriptionNot set
QA Service Level1 (Verified on 06/26/2024)

Sample Information

Sample Taken Date05/09/2025 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/15/2025
Sample typeQuality Assurance A brief description of the sample4 samples (1 lot) of #6 Rebar with HRC 500/510 Couplers
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byAlvarez
Title of samplerQuality Assurance Inspector Telephone number of sampler2094301848
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCamblin Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelHRC 500 /510 XTender
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)100012324240 Rebar Heat Number(s)3500039081
Rebar Size 2 Coupler Unique IDTP-17-03

Test Details

DIME Sample ID: 2025-05-09-11
DIME Test ID: 2025-05-09-11-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-05-27

Test Results


Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 05/27/2025
UTM: NA
Halo ID: na
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11160.440.0024005091000ok neckingKleinfelder
22160.4400004079092500ok neckingKleinfelder
33160.4400004090093000ok neckingKleinfelder
44160.4400004037092000ok neckingKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/27/2025