Summary for Test 2017-10-03-5-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 210696 DEA: 080M2804 EFIS: 0800000472 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-171.8/173.8 |
| Award Date | 11/04/2015 |
| Closeout Date | 08/21/2018 |
| Work Description | BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT. |
| Location Description | In SBD County |
| QA Service Level | 1 (Verified on 10/19/2015) |
Sample Information
| Sample Taken Date | 10/03/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/23/2017 | Sample type | Quality Assurance |
| A brief description of the sample | 6x12 | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | ABRAHAM |
| Last name of sampler or witnessed by | Almaw | Title of sampler | ASR |
| Telephone number of sampler | Unknown | Laboratory sample identification | 942-03A |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | CALPORTLAND |
| Transportation Laboratory (TL) Number | 20171003A | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | CENDA BRIDGE | Structure name | CENDA BRIDGE |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | P40AF033SRA |
|---|---|---|---|
| The truck number from where the sample was collected | 8031 | The batch plant ticket number from where the sample was collected | S517060 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | TRUCK | Where the material sample would have been placed if not sampled | CENDA Bridge DECK |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-10-03-5
DIME Test ID: 2017-10-03-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-10-24
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 10/24/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 140130 lb
Maximum load on cylinder 2: 140830 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 21 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4956.8 psi
Compressive strength of cylinder 2: 4981.6 psi
Compressive strength (to nearest 10 psi): 4970 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/24/2017 ✔