Summary for Test 2025-04-28-58-7

Test performed: AASHTO R28-22

Project Information

Project IdentifiersProject ID: 1000414
DEA: 034H8704
EFIS: 0319000070
DIST-CO-RTE-PM03-SUT-99-25.0/26.2
Award Date10/09/2024
Closeout DateNot set
Work DescriptionRDWY EXC, PLACE HMA-A AND CRCP, INSTALL SIGNAL AND LIGHTING.
Location DescriptionSUTTER COUNTY NEAR YUBA CITY FROM 0.6 MILE SOUTH TO 0.6 MILE NORTH OF OSWALD ROAD
QA Service Level1 (Verified on 07/30/2024)

Sample Information

Sample Taken Date04/28/2025 Sample Unique Key58
Date that the sample was received by the laboratory/organization performing the testing05/12/2025 Sample typeProduction Start-Up
A brief description of the sample1 can PG 64-16 binder The quantity of what the sample constitutes3/4" HMA w/ 15% RAP
From where was the sample collectedSource First name of sampler or witnessed byBrad
Last name of sampler or witnessed byMcKeehan Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Hallwood
Transportation Laboratory (TL) NumberC778927 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-04-28-58
DIME Test ID: 2025-04-28-58-7
Testing Lab: Atlas - Denver
Test Method: AASHTO R28-22: Accelerated Aging of Asphalt Binder Using a Pressurized Aging Vessel (PAV)
Test Release Date: 2025-05-23

Test Results


Input Type: Calculated
Tester's full name: Atlas Denver
Date of test: 05/20/2025
Sample identification: 2025-04-28-58
Aging Test Temperature, nearest 0.5 C: 100.0 C
Minimum aging temperature recorded: 100.0 C
Maximum aging temperature recorded: 100.0 C
Total time during aging that temperature was outside the specified range: 0 minutes
Total aging time (hour): 20 hours
Total aging time (minute): 0 minutes
The heating temperature: 100 C
General comments (publicly viewable) (Max 1000 characters): PAV @100C

Test was verified on 5/23/2025 ✔