Summary for Test 2025-04-24-10-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000264
DEA: 060W90U4
EFIS: 0623000128
DIST-CO-RTE-PM06-TUL-198,216-R11.6/R11.9,R0.0/2.7
Award Date08/29/2024
Closeout DateNot set
Work DescriptionHMA AND MODIFYING SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionTULARE COUNTY IN AND NEAR VISALIA ON ROUTE 216 FROM 0.2 MILE SOUTH OF LOVERS LANE UNDERCROSSING TO 0.2 MILE EAST OF MCAULIFF STREET AND ON ROUTE 198 FROM 0.1 MILE WEST TO 0.2 MILE EAST OF LOVERS LANE UNDERCROSSING
QA Service Level1 (Verified on 04/15/2024)

Sample Information

Sample Taken Date04/24/2025 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing04/25/2025 Sample typeQuality Assurance
A brief description of the sampleRetaining wall The quantity of what the sample constitutes64
From where was the sample collectedJob Site First name of sampler or witnessed byAdam
Last name of sampler or witnessed byMahmoud Title of samplerASR
Telephone number of sampler Laboratory sample identification63
Linked DIME Sample ID The fabricator/manufacturer/facility nameCalportland farmersville
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number172457
The truck number from where the sample was collected0713 The batch plant ticket number from where the sample was collected234245
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampledRetaining wall stem
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-04-24-10
DIME Test ID: 2025-04-24-10-3
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-05-23

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jason Ruiz
Date of test: 05/22/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 56847 lb
Maximum load on cylinder 2: 59446 lb
Maximum load on cylinder 3: 61519 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4522.4 psi
Compressive strength of cylinder 2: 4729.2 psi
Compressive strength of cylinder 3: 4894.1 psi
Compressive strength (to nearest 10 psi): 4720 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/23/2025 ✔