Summary for Test 2025-05-14-1-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Sample Information

Sample Taken Date05/14/2025 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing05/19/2025 Sample typeQuality Assurance
A brief description of the sample#14 bar HRC 500/510 Couplers The quantity of what the sample constitutes4 samples from lot #2
From where was the sample collectedFabricator First name of sampler or witnessed byOsiel
Last name of sampler or witnessed by RAMIREZ Title of samplerQuality Assurance Inspector
Telephone number of sampler(916) 767 3535 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameIntegrity Rebar Placers
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL123-032-25
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Steel
Coupler ManufacturerHRC Intermediate Assembler or FabricatorIntegrity Rebar Placers
Rebar Size#14 Coupler ModelExtender 500 510 Standar
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)74132985, 73132890 Rebar Heat Number(s)186422, 435322
Rebar Size 2 Coupler Unique IDTP-17-03

Test Details

DIME Sample ID: 2025-05-14-1
DIME Test ID: 2025-05-14-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-05-22

Test Results


Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 05/22/2025
UTM: NA
Halo ID: na
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111142.250.02821663096500ok neckingKleinfelder
221142.25000021705096500ok neckingKleinfelder
331142.25000021682096500ok neckingKleinfelder
441142.25000021796097000ok neckingKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/22/2025 ✔