Summary for Test 2025-05-20-3-4

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 1000369
DEA: 09378804
EFIS: 0919000002
DIST-CO-RTE-PM09-MNO-395-R9.8/R12.6
Award Date08/29/2024
Closeout DateNot set
Work DescriptionPLACE HMA AND ASPHALT BASE, RECYCLE PAVEMENT AND MODIFY ELECTRICAL.
Location DescriptionMONO COUNTY NEAR TOM\\\\\\\\\\\\\\\\'S PLACE FROM 0.5 MILE NORTH OF LOWER ROCK CREEK ROAD TO 1.3 MILES SOUTH OF SOUTH LANDING OVERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date05/20/2025 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing05/20/2025 Sample typeProduction Start-Up
A brief description of the sample3/4" Coldfeed & RAP The quantity of what the sample constitutes750 Tons
From where was the sample collectedSource First name of sampler or witnessed byJosh
Last name of sampler or witnessed byHubbart Title of samplerTET
Telephone number of sampler Laboratory sample identification4589
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite 5 Bridges Plant
Transportation Laboratory (TL) NumberPSU-01 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-14-0001
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSample Device at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-05-20-3
DIME Test ID: 2025-05-20-3-4
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2025-05-20

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 05/20/2025
Bulk dry specific gravity: 2.61
Average uncompacted voids: 45.2 %
General comments (publicly viewable) (Max 1000 characters): PSU-01 CF

Test was verified on 5/20/2025 ✔