Summary for Test 2025-05-14-46-9

Test performed: AASHTO T315-24

Project Information

Project IdentifiersProject ID: 1000636
DEA: 024H03U4
EFIS: 0224000026
DIST-CO-RTE-PM02-PLU-89-12.9/20.0,20.6/21.0
Award Date12/20/2024
Closeout DateNot set
Work DescriptionHMA OVERLAY.
Location DescriptionPLUMAS COUNTY IN AND NEAR GREENVILLE FROM 0.8 MILE SOUTH OF DIXIE CANYON ROAD TO WOLF CREEK BRIDGE AND FROM MILL STREET TO 0.4 MILE NORTH OF HILLSIDE DRIVE
QA Service Level1 (Verified on 09/24/2024)

Sample Information

Sample Taken Date05/14/2025 Sample Unique Key46
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/20/2025
Sample typeQuality Assurance A brief description of the samplePG 58-34
The quantity of what the sample constitutes2 Cans From where was the sample collectedSource
First name of sampler or witnessed byS Last name of sampler or witnessed byL
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWard Lake Transportation Laboratory (TL) Number857979
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierAlbina Asphalt (Klamath Falls Plant) - Klamath Falls OR MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-05-14-46
DIME Test ID: 2025-05-14-46-9
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2025-06-06

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Luis Maca
Date of test: 06/06/2025
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.143 kPa
Phase Angle (δ) (for the 10 cycles): 82.5 degree
Complex Modulus (G*) (for the 10 measurements): 1.183 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 1.19 kPa
General comments (publicly viewable) (Max 1000 characters): Original

Test was verified on 6/6/2025