Summary for Test 2025-04-15-89-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215741
DEA: 01366004
EFIS: 0100000127
DIST-CO-RTE-PM01-HUM-101-80.0/84.0
Award Date12/29/2022
Closeout DateNot set
Work DescriptionIndianola Cutoff UC
Location DescriptionHUMBOLDT COUNTY NEAR EUREKA FROM EUREKA SLOUGH BRIDGE TO BAYSIDE CUTOFF
QA Service Level1 (Verified on 05/17/2021)

Sample Information

Sample Taken Date04/15/2025 Sample Unique Key89
Date that the sample was received by the laboratory/organization performing the testing04/16/2025 Sample typeQuality Control
A brief description of the samplePCC The quantity of what the sample constitutes480 CY
From where was the sample collectedJob Site First name of sampler or witnessed byZack
Last name of sampler or witnessed byArnold Title of sampler
Telephone number of sampler Laboratory sample identificationC9835
Linked DIME Sample ID The fabricator/manufacturer/facility nameEureka Ready Mix
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameBridge Deck
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberE750FBR
The truck number from where the sample was collected77 The batch plant ticket number from where the sample was collected41682
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSample from Concrete Truck, wheelbarrow Where the material sample would have been placed if not sampledBridge Deck
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-04-15-89
DIME Test ID: 2025-04-15-89-5
Testing Lab: SHN Engineers & Geologists, Incorporated
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-05-19

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Dave Gonzales
Date of test: 04/22/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 56040 lb
Type of fracture pattern of cylinder 1: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 4460 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/19/2025 ✔