Summary for Test 2025-05-12-52-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994321
DEA: 040K1604
EFIS: 0416000044
DIST-CO-RTE-PM04-ALA,CC-80-R7.6/8.0,0.0/13.5
Award Date02/08/2023
Closeout DateNot set
Work DescriptionCONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER.
Location DescriptionALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET
QA Service Level1 (Verified on 10/14/2022)

Sample Information

Sample Taken Date05/12/2025 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/13/2025
Sample typeQuality Assurance A brief description of the sampleBatch Plant OGFC-O
The quantity of what the sample constitutes2 One Gallon Cans From where was the sample collectedFabricator
First name of sampler or witnessed byIGNACIO Last name of sampler or witnessed byARECHIGA
Title of samplerLab Technician Telephone number of sampler5102077252
Laboratory sample identificationRich_24_169 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCounty Asphalt Martinez Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix NumberID L250530
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-05-12-52
DIME Test ID: 2025-05-12-52-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-05-19

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 05/19/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1547.8 g
Mass Loss: 127.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.80 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.35 %
General comments (publicly viewable) (Max 1000 characters): Lot 1 SL 1 oil failed @ 7.3 % Range 7.5 - 8.4

Test was verified on 5/19/2025