Summary for Test 2025-04-30-53-4

Test performed: CTM 217-June 2011
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 210160
DEA: 101E2204
EFIS: 1015000011
COOP: 10439
DIST-CO-RTE-PM10-SJ-580-13.3/13.8
Award DateNot set
Closeout DateNot set
Work DescriptionWiden existing road under I-580 to accommodate ramp widening and additional left turn lanes . Proposes to replace existing two lane bridge over the adjacent California Aqueduct on the east side of the Interchange and add two additional lanes
Location DescriptionBetween I-580 and Old Schulte Road
QA Service Level2 (Verified on 01/30/2015)

Sample Information

Sample Taken Date04/30/2025 Sample Unique Key53
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/01/2025
Sample typeQuality Control A brief description of the sample1x4 Aggregates
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byMohsen Last name of sampler or witnessed byNoshad
Title of samplerField Technician Telephone number of sampler
Laboratory sample identification289285 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Tracy Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Batch plant
The fabricator's/manufacturer's product name for the sampleCemex Tracy The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBatch Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number1616182 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-04-30-53
DIME Test ID: 2025-04-30-53-4
Testing Lab: Construction Testing Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-05-19

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: Lonei Banaag
Date of test: 05/19/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.1
Sand reading (test 1): 3.1
Clay reading (test 2): 4.2
Sand reading (test 2): 3.1
Clay reading (test 3): 4
Sand reading (test 3): 3
Sand equivalent (test 1): 76
Sand equivalent (test 2): 74
Sand equivalent (test 3): 75
Sand equivalent before temperature correction: 75
Sand equivalent after temperature correction: 75
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/19/2025

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.