Summary for Test 2025-03-21-42-4
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 1000314 DEA: 042Y5804 EFIS: 0423000130 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-1-30.5/32.0 |
| Award Date | 06/24/2024 |
| Closeout Date | 09/29/2025 |
| Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH HMA. |
| Location Description | SONOMA COUNTY AT FORT ROSS FROM 2.5 MILES SOUTH OF FORT ROSS ROAD TO 1.0 MILE SOUTH OF FORT ROSS ROAD |
| QA Service Level | 1 (Verified on 12/02/2024) |
Sample Information
| Sample Taken Date | 03/21/2025 | Sample Unique Key | 42 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/24/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" hma wma |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Casey | Last name of sampler or witnessed by | Farrington |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | BoDean Company | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | 700SPW16 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-03-21-42
DIME Test ID: 2025-03-21-42-4
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2025-05-19
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?: Field compacted
Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 04/01/2025
| 1 | 2 | 3 | ||||
|---|---|---|---|---|---|---|
| 2.448 | 2.452 | 2.455 | ||||
| 2.49 | ||||||
1.7 % | 1.5 % | 1.4 % | ||||
1.5 % | ||||||
98.5 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/19/2025 ✔