Summary for Test 2025-05-14-27-2

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 5016
DEA: 080K8004
DIST-CO-RTE-PM08-SBd-395-51.9/58.1,61.0/65.6
Award Date06/16/2009
Closeout Date07/29/2010
Work DescriptionOVERLAY RUBBERIZED HOT MIX ASPHALT AND DIG OUTS
Location DescriptionNot set
QA Service Level1 (Verified on 07/29/2010)

Sample Information

Sample Taken Date05/14/2025 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2025
Sample typeQuality Assurance A brief description of the sampleRecycle Class 2 Aggregate Base
The quantity of what the sample constitutes2 Cylinder's From where was the sample collectedJob Site
First name of sampler or witnessed byIGNACIO Last name of sampler or witnessed byARECHIGA
Title of sampler Telephone number of sampler5102077252
Laboratory sample identificationRich_25_161 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGhilotti silveria Yard Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Job site
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedfrom the mat / @ Job site
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-05-14-27
DIME Test ID: 2025-05-14-27-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-05-15

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 05/14/2025
Sum of Count or Density: 69813 g/cc
Average of Count or Density: 23271 g/cc
Sum of Moisture Count: 9469 g/cc
Average of Moisture Count: 3156 g/cc
Count Ratio Density: 2.3
Count Ratio Moisture: 0.31
Calculated Percent Relative Compaction: 100.4 %
Reported Percent Relative Compaction: 100 %
General comments (publicly viewable) (Max 1000 characters): Recycle Class 2 AB For Compaction test

Test was verified on 5/15/2025