Summary for Test 2025-04-08-32-13
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 994751 DEA: 010C5004 EFIS: 0112000292 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-36-11.3/34.6 |
| Award Date | 03/02/2023 |
| Closeout Date | Not set |
| Work Description | Project Name: Bridge Rail Replacement - 3 Bridges |
| Location Description | Hely Creek, Little Larabee Creek and Butte Creek Bridge. |
| QA Service Level | 1 (Verified on 04/27/2023) |
Sample Information
| Sample Taken Date | 04/08/2025 | Sample Unique Key | 32 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/11/2025 |
| Sample type | Verification | A brief description of the sample | 1 can PG 64-16 binder |
| The quantity of what the sample constitutes | 1 can of binder | From where was the sample collected | Source |
| First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Reeves |
| Title of sampler | QC Technician | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Mercer Fraser Boyd Road | Transportation Laboratory (TL) Number | 00000 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-04-08-32
DIME Test ID: 2025-04-08-32-13
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-05-15
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Atlas Denver
Date of test: 05/07/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 208.191 grams
Mass of container #2 before test (m2i): 207.777 grams
Mass of container #1 after test (m1f): 208.102 grams
Mass of container #2 after test (m2f): 207.696 grams
Mass of empty container #1: 173.588 grams
Mass of empty container #2: 172.874 grams
Mass correction factor: 0.030
Average mass change: -0.215 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change
Test was verified on 5/15/2025 ✔