Summary for Test 2025-04-14-47-6
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 994785 DEA: 023H32U4 EFIS: 0221000164 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-I5-2.5/R15.9 |
| Award Date | 04/28/2023 |
| Closeout Date | Not set |
| Work Description | Roadway rehabilitation and bridge improvements along I5 in Mount Shasta |
| Location Description | SIS I5 2.5/R15.9 |
| QA Service Level | 1 (Verified on 05/03/2023) |
Sample Information
| Sample Taken Date | 04/14/2025 | Sample Unique Key | 47 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2024 |
| Sample type | Production Start-Up | A brief description of the sample | PG58-34M |
| The quantity of what the sample constitutes | 2 cans | From where was the sample collected | Source |
| First name of sampler or witnessed by | G | Last name of sampler or witnessed by | Giuntoli |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Valero Benicia | Transportation Laboratory (TL) Number | 823557 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
|---|---|---|---|
| Modified | Yes | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | Tullis Northstate Asphalt | |
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-04-14-47
DIME Test ID: 2025-04-14-47-6
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-05-14
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Atlas Denver
Date of test: 05/08/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 208.491 grams
Mass of container #2 before test (m2i): 210.204 grams
Mass of container #1 after test (m1f): 208.360 grams
Mass of container #2 after test (m2f): 210.091 grams
Mass of empty container #1: 173.259 grams
Mass of empty container #2: 175.248 grams
Mass correction factor: 0.030
Average mass change: -0.318 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change
Test was verified on 5/14/2025 ✔