Summary for Test 2025-04-15-36-8
Test performed: AASHTO T316-22Project Information
| Project Identifiers | Project ID: 995524 DEA: 021H3604 EFIS: 0216000040 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-96-76.8/78.0 |
| Award Date | 03/22/2024 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SISKIYOU COUNTY NEAR HORSE CREEK FROM 0.4 MILE WEST OF KLAMATH RIVER BRIDGE TO 2.0 MILES WEST OF KOHL CREEK |
| QA Service Level | 1 (Verified on 12/27/2023) |
Sample Information
| Sample Taken Date | 04/15/2025 | Sample Unique Key | 36 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/18/2025 |
| Sample type | Quality Assurance | A brief description of the sample | PG 58-34 non-modified |
| The quantity of what the sample constitutes | 2 cans | From where was the sample collected | Source |
| First name of sampler or witnessed by | G | Last name of sampler or witnessed by | Giuntoli |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Tullis Inc. - Northstate Asphalt (Redding CA) | Transportation Laboratory (TL) Number | 823560 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-34 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-04-15-36
DIME Test ID: 2025-04-15-36-8
Testing Lab: Atlas - Denver
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-05-15
Test Results
Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: Atlas Denver
Date of test: 05/08/2025
Time of test: 09:00 HH:MM
Test Temperature: 135.0 C
Speed: 20 rpm
Spindle size: 0.463 in
Torque: 17.2 %
Viscosity reading #1 (A) : 430 cP
Viscosity reading #2 (B) : 429.9 cP
Viscosity reading #3 (C): 430 cP
Average viscosity : 0.43 Pa-s
General comments (publicly viewable) (Max 1000 characters): Viscosity @135C
Test was verified on 5/15/2025 ✔