Summary for Test 2025-04-15-36-7

Test performed: AASHTO R28-22

Project Information

Project IdentifiersProject ID: 995524
DEA: 021H3604
EFIS: 0216000040
DIST-CO-RTE-PM02-SIS-96-76.8/78.0
Award Date03/22/2024
Closeout Date12/29/2025
Work DescriptionREPLACE BRIDGE.
Location DescriptionSISKIYOU COUNTY NEAR HORSE CREEK FROM 0.4 MILE WEST OF KLAMATH RIVER BRIDGE TO 2.0 MILES WEST OF KOHL CREEK
QA Service Level1 (Verified on 12/27/2023)

Sample Information

Sample Taken Date04/15/2025 Sample Unique Key36
Date that the sample was received by the laboratory/organization performing the testing04/18/2025 Sample typeQuality Assurance
A brief description of the samplePG 58-34 non-modified The quantity of what the sample constitutes2 cans
From where was the sample collectedSource First name of sampler or witnessed byG
Last name of sampler or witnessed byGiuntoli Title of samplerConsultant
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTullis Inc. - Northstate Asphalt (Redding CA)
Transportation Laboratory (TL) Number823560 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-04-15-36
DIME Test ID: 2025-04-15-36-7
Testing Lab: Atlas - Denver
Test Method: AASHTO R28-22: Accelerated Aging of Asphalt Binder Using a Pressurized Aging Vessel (PAV)
Test Release Date: 2025-05-15

Test Results


Input Type: Calculated
Tester's full name: Atlas Denver
Date of test: 05/07/2025
Sample identification: 2025-04-15-36
Aging Test Temperature, nearest 0.5 C: 100.0 C
Minimum aging temperature recorded: 100.0 C
Maximum aging temperature recorded: 100.0 C
Total time during aging that temperature was outside the specified range: 0 minutes
Total aging time (hour): 20 hours
Total aging time (minute): 0 minutes
The heating temperature: 100 C
General comments (publicly viewable) (Max 1000 characters): PAV @100C

Test was verified on 5/15/2025 ✔