Summary for Test 2025-04-17-50-6

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1001208
DEA: 022K6204
EFIS: 0225000120
DIST-CO-RTE-PM02-SIS-96-46.6/46.6
Award Date02/28/2025
Closeout Date07/14/2025
Work DescriptionSiskiyou 96 Potential Landslide DO Storm Damage
Location DescriptionIN SISKIYOU COUNTY NEAR HAPPY CAMP AT 2.3 MILES EAST OF GORDONS FERRY ROAD
QA Service Level1 (Verified on 04/22/2025)

Sample Information

Sample Taken Date04/17/2025 Sample Unique Key50
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/24/2025
Sample typeQuality Assurance A brief description of the samplePG 58-22
The quantity of what the sample constitutes2 cans From where was the sample collectedSource
First name of sampler or witnessed byGiantolis Last name of sampler or witnessed byTanner
Title of samplerTester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameJF Shea Fawndale Transportation Laboratory (TL) Number823564
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeYes
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-04-17-50
DIME Test ID: 2025-04-17-50-6
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-05-15

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Atlas Denver
Date of test: 05/07/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 209.172 grams
Mass of container #2 before test (m2i): 210.644 grams
Mass of container #1 after test (m1f): 208.957 grams
Mass of container #2 after test (m2f): 210.488 grams
Mass of empty container #1: 174.501 grams
Mass of empty container #2: 176.040 grams
Mass correction factor: 0.030
Average mass change: -0.505 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change

Test was verified on 5/15/2025