Summary for Test 2025-05-13-11-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 994766
DEA: 042W4504
EFIS: 0421000205
DIST-CO-RTE-PM04-SCL-87-1.5,4.8
Award Date05/02/2024
Closeout Date02/02/2026
Work DescriptionMASONRY SOUND WALL, CAST-IN-PLACE SOUND WALL, AND CIDH PILE.
Location DescriptionSANTA CLARA COUNTY IN SAN JOSE AT NARVAEZ AVENUE AND NEAR WEST VIRGINIA STREET
QA Service Level1 (Verified on 05/09/2023)

Sample Information

Sample Taken Date05/13/2025 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing05/13/2025 Sample typeQuality Assurance
A brief description of the sampleNative Structure Backfill Material The quantity of what the sample constitutes2500 Grams
From where was the sample collectedJob Site First name of sampler or witnessed byJacob
Last name of sampler or witnessed byVega Title of samplerConsultant QA
Telephone number of sampler Laboratory sample identificationSJ-051325-SBF1
Linked DIME Sample ID The fabricator/manufacturer/facility nameNative
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedVarious locations at Native Structural Backfill
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-05-13-11
DIME Test ID: 2025-05-13-11-1
Testing Lab: CT D04 - San Jose Construction Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-05-13

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 05/13/2025
Sum of Count or Density: 108996 g/cc
Average of Count or Density: 36332 g/cc
Sum of Moisture Count: 13333 g/cc
Average of Moisture Count: 4444 g/cc
Calculated Percent Relative Compaction: 90.1 %
Reported Percent Relative Compaction: 90 %
General comments (publicly viewable) (Max 1000 characters): 801 Prevost St. "SWR1" LoL Hwy 87 SB to Hwy 85 Masonry Sound Wall

Test was verified on 5/13/2025 ✔