Summary for Test 2025-04-03-20-19
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/03/2025 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/21/2025 |
| Sample type | Stock | A brief description of the sample | 1" x 5" F3125 (A325) Hex Bolt Mech Galv B695 Class 55 Rocap |
| The quantity of what the sample constitutes | 3000 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Levi | Last name of sampler or witnessed by | Pivoda |
| Title of sampler | Telephone number of sampler | 9152961871 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S88-405-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 10896560 234317 147259 | Nut Mfg. Lot Number(s) | 38872-S-234317 |
| Washer Mfg. Lot Number(s) | 147259 / 38545 | Bolt Specification | ASTM F3125 Grade A325 |
| Bolt Length(s) | 5" | Nut Specification | ASTM A563 Grade DH |
| Washer Specification | ASTM F436 | Finish | ASTM B6905 Class 55 |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | BM1382 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2025-04-03-20
DIME Test ID: 2025-04-03-20-19
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2025-05-21
Test Results
Number of Samples: 3
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 05/13/2025
UTM: NA
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | BM1382 | 1 | 86710 | 0 | NA | W Torres |
| 2 | 1B | BM1382 | 1 | 87330 | 0 | NA | W Torres |
| 3 | 1C | BM1382 | 1 | 87400 | 0 | NA | W Torres |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/21/2025 ✔