Summary for Test 2025-05-05-50-1

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 993825
DEA: 040Q30U4
EFIS: 0420000235
COOP: 042830A3,042830A4
DIST-CO-RTE-PM04-ALA,CC-680-R11.0/R21.9,R0.0/R0.9
Award Date11/23/2022
Closeout DateNot set
Work DescriptionPRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC
Location DescriptionALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date05/05/2025 Sample Unique Key50
Date that the sample was received by the laboratory/organization performing the testing05/09/2025 Sample typeQuality Assurance
A brief description of the sample1/2"HMA w/25% RAP The quantity of what the sample constitutes750 Tons
From where was the sample collectedJob Site First name of sampler or witnessed byBhalinder
Last name of sampler or witnessed byPandher Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Pleasanton
Transportation Laboratory (TL) NumberC505251 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number2
Sublot number8 HMA Mix Number320302W
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-05-05-50
DIME Test ID: 2025-05-05-50-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-05-12

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Robert Lohman
Date of test: 05/12/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7334.8 grams
Mass of oven-dry sample in air for Sample 1: 1540.2 grams
Mass of container filled with the sample and water for Sample 1: 8253.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.480
Theoretical maximum density at 25°C (77°F): 2473 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Lot 2 SL 8

Test was verified on 5/12/2025 ✔