Summary for Test 2025-05-07-11-6
Test performed: CTM 227-December 2014Project Information
| Project Identifiers | Project ID: 994901 DEA: 112T3434 EFIS: 1120000081 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-5.1/8.3 |
| Award Date | 01/29/2024 |
| Closeout Date | Not set |
| Work Description | SOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 03/21/2024) |
Sample Information
| Sample Taken Date | 05/07/2025 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/08/2025 |
| Sample type | Quality Control | A brief description of the sample | 1x4 concrete aggregates |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 25-05-07-11-S | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Associated Ready Mix - Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0035 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | stockpile or belt cut | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | 55723740SRP3F | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-05-07-11
DIME Test ID: 2025-05-07-11-6
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2025-05-09
Test Results
Describe the gradation of the aggregate or the test method:: Mix of sizes - max 1.5 in.
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 05/09/2025
Top sediment column reading (11/2 in. x 3/4 in.): 0.0 in
Top sediment column reading (1 in. x No. 4): 0.3 in
Cleanness value (11/2 in. x 3/4 in.): 100.0
Cleanness value (1 in. x No. 4): 91.3
Cleanness value (11/2 in. maximum aggregate mix): 95
General comments (publicly viewable) (Max 1000 characters): 3/8"
Test was verified on 5/9/2025 ✔