Summary for Test 2025-04-22-87-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1001178 DEA: 020J3904 EFIS: 0219000112 |
|---|---|
| DIST-CO-RTE-PM | 02--- |
| Award Date | 08/01/2024 |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 2 (Verified on 04/14/2025) |
Sample Information
| Sample Taken Date | 04/22/2025 | Sample Unique Key | 87 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/23/2025 | Sample type | Production Start-Up |
| A brief description of the sample | 16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) | The quantity of what the sample constitutes | Production Start-Up Evaluation |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Cindy |
| Last name of sampler or witnessed by | Bryant | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | D79860 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | J.F. Shea Construction — Fawndale Rock and Asphalt (Redding, CA) | |
| Transportation Laboratory (TL) Number | 823624 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-04-22-87
DIME Test ID: 2025-04-22-87-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-05-09
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 04/23/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7332.2 grams
Mass of oven-dry sample in air for Sample 1: 2559.6 grams
Mass of container filled with the sample and water for Sample 1: 8905.6 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.595
Theoretical maximum density at 25°C (77°F): 2587.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmm=2.595
Test was verified on 5/9/2025 ✔