Summary for Test 2025-05-01-52-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 995193
DEA: 07356604
EFIS: 0719000026
DIST-CO-RTE-PM07-LA-605-R10.2/20.2
Award Date04/04/2024
Closeout DateNot set
Work DescriptionLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
QA Service Level1 (Verified on 10/03/2023)

Sample Information

Sample Taken Date05/01/2025 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/01/2025
Sample typeAcceptance A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes100 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byHonesto Last name of sampler or witnessed byCastillo
Title of samplerMREAS Telephone number of sampler2134537563
Laboratory sample identification014B Linked DIME Sample ID2025-05-01-51
The fabricator/manufacturer/facility nameMyers & Sons Whittier Staging Yard Transportation Laboratory (TL) NumberC 003467
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0025
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedContractor's Whittier Staging Yard Stockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design numberVCTS675 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-05-01-52
DIME Test ID: 2025-05-01-52-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-05-29

Test Results


Number of tests: 2
Input Type: Measured
Tester's full name: Honesto Castillo
Date of test: 05/08/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.9
Sand reading (test 1): 4.2
Clay reading (test 2): 4.9
Sand reading (test 2): 4.3
Sand equivalent (test 1): 86
Sand equivalent (test 2): 88
Sand equivalent before temperature correction: 87
Sand equivalent after temperature correction: 87
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/29/2025