Summary for Test 2025-05-01-51-2

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 995193
DEA: 07356604
EFIS: 0719000026
DIST-CO-RTE-PM07-LA-605-R10.2/20.2
Award Date04/04/2024
Closeout DateNot set
Work DescriptionLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
QA Service Level1 (Verified on 10/03/2023)

Sample Information

Sample Taken Date05/01/2025 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/01/2025
Sample typeAcceptance A brief description of the sample1 x No. 4 PCC Aggregate
The quantity of what the sample constitutes100CY From where was the sample collectedManufacturer
First name of sampler or witnessed byHonesto Last name of sampler or witnessed byCastillo
Title of samplerMREAS Telephone number of sampler2134537563
Laboratory sample identification014A Linked DIME Sample ID2025-05-01-52
The fabricator/manufacturer/facility nameMyers & Sons Whittier Staging Yard Transportation Laboratory (TL) NumberC 003466
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0025
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedContractor's Whittier Yard Stockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberVCTS675 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-05-01-51
DIME Test ID: 2025-05-01-51-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2025-05-29

Test Results


Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Honesto Castillo
Date of test: 05/07/2025
Top sediment column reading (single primary size): 0.6 in
Cleanness value (single primary size): 84
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/29/2025