Summary for Test 2025-04-11-3-5
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1000580 DEA: 071XW104 EFIS: 0723000028 |
|---|---|
| DIST-CO-RTE-PM | 07--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | VENTURA COUNTY IN CITY OF FILLMORE VEN-126REPLACE/CONSTRUCT THE FILLMORE MAINTENANCESTATION DAMAGED BY HIGH WINDS DIR\\'S EMERGENCY |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 09/09/2024) |
Sample Information
| Sample Taken Date | 04/11/2025 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/17/2025 |
| Sample type | Quality Assurance | A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts |
| The quantity of what the sample constitutes | 2 of 48 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
| Title of sampler | QA | Telephone number of sampler | 7029172503 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Blue Circle Corp | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-032-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 1201061488 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 |
| Bolt Length(s) | 18" - 38" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | ASTM F2329 |
| Diameter/Size | 3/4 | Bolt Mfg. Lot Number | 18 inch lot 99285-1 ; 36 inch lot 99285-2 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2025-04-11-3
DIME Test ID: 2025-04-11-3-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2025-05-08
Test Results
Number of Samples: 1
Input Type: Calculated
Tester's full name: She Vang
Date of test: 05/08/2025
UTM: NA
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 0.75 x38" | 0.334 | 29070 | 129 | 87036 | 64611 | 21580 | lot 99285-2 |
General comments (publicly viewable) (Max 1000 characters): Tested by Kleinfelder Lab
Test was verified on 5/8/2025 ✔